Analyseur de caractéristiques voltampères UHV-300 CT PT
L'analyseur de caractéristiques de volts-ampères UHV-300 CT PT est un instrument de test professionnel pour les transformateurs dans l'industrie électrique et adopte un DSP et un ARM hautes performances, un processus de fabrication avancé.
Détails du produit de l'analyseur de caractéristiques de voltampère UHV-300 CT PT
Introduction
The UHV-300 CT PT Tester is used for testing both current transformers (CT) and voltage transformers (VT). It performs key measurements such as the excitation characteristics and excitation parameters of instrument transformers. Additionally, it is capable of conducting turns ratio tests, polarity checks, and winding resistance measurements on transformer coils. Specifically for voltage transformers, it is employed for excitation characteristic testing, PT turns ratio verification, and PT polarity inspection.
The main parameters
Usage
Protection CT, protection PT
Sortir
0~180Vrms,12Arms,18A(Peak)
Précision de la mesure de tension
±0.2%
Mesure du rapport CT
Range:1~40000
Accuracy: ±0.2% ±0.05% (customizable)
Mesure du rapport PT
Range:1~40000
accuracy:±0.2%
Mesure de phase
The resolution of the:0.5min
accuracy:±5min
Mesure de la résistance de l'enroulement secondaire
Range:0~300Ω
accuracy:2%±2mΩ
Mesure de charge CA
Range:0~300VA
accuracy:2%±0.2VA
source de courant
AC220V ± 10%, 50Hz
Environnement de travail
Temperature: -10℃ ~ 50℃, humidity: ≤90%
Dimensions et poids
size:340mm×220mm×330m,The weight of the:≤9kg
Characteristics
1、Full-featured, not only satisfy the test requirements of various CTs (include TP class), such as the excitation characteristics (i.e., volt-ampere characteristics), ratio, polarity, secondary winding resistance, secondary burden, ratio error and phase displacement, but can also be used for the tests of various PTs, including excitation characteristics of the electromagnetic unit, ratio, polarity, secondary winding resistance, ratio error and phase displacement.
2、 Automatically give CT, VT parameters, including knee point voltage / current, 10% error curve, the accuracy limit factor (ALF), instrument security factor (FS), the second time constant (Ts), remanence coefficient (Kr), saturated and unsaturated inductance etc.
3、Test meet IEC60044 GB1208 (-1) GB16847 (IEC60044-6) became etc all kinds of transformer standards, and in accordance with the transformer types and levels of automatic choose which standard test.
4、Based on the advanced low-frequency method to test principle of, it can deal with CT test with inflection point up to 30kV.
5、Interface friendly and beautiful, Chinese graphics interface.
6、The device can store 2000 sets of test data without loss when power is lost.After the test, use U disk to store it on the PC, analyze the data with the software, and generate WORD report.
7、The test is simple and convenient. The direct resistance, excitation, ratio change and polarity tests of CT are completed with one key. Besides the load test, all other tests of CT adopt the same wiring mode.